State Of The Art Software & Technology.          As featured on BBC2 TV  Newsnight.

Home of   Eco Warrior   &   Reporter Professional      
Energy Saving - Bill Checking  - Tenant Billing -  Automated Metering - Energy Logging - All Energy Solutions Are Here !
Home Up

 

 

FIREWORKS COMBUSTION GRAPHER

Communications, Graphs & Reports for the Kane Quintox Gas Analyser.

bullet Designed specifically for the user requiring the maximum from their emissions monitoring data.
bullet Analysis is made easy by using graphs, tables and reports generated from your combustion tests.
bullet Real-time data logging allows you to see important changes to the boiler as they happen.
bullet A simple to use Windows package is designed to enable modified reports for your client and stored tests for your analysis.

Data can be quickly and easily loaded from a Kane-May combustion analyser or from a previous file saved by the Combustion Grapher.  Additionally Grapher has a real time mode.

The data can be easily viewed in a spreadsheet format.  Moving around the table is simple and quick, real time data can be viewed as it is received from the analyser.

Viewing data in a graph is often the clearest way to understand information.  The Grapher will show exactly what you need at the touch of a button.  There is a colour coded display for each parameter including minimum and maximum levels.

The graph allows you to see the running profile of a boiler showing start-up, running and shutdown emissions.

Features include graphs, multi-data Snapshot view and large simulated LED format, all of which can be utilised whilst receiving real time combustion data.

The versatile report function creates perfect and clear printouts of the data you request.  The different options include Spot checks, Tuning and Emissions reports allowing you to calculate daily, monthly and annual toxic gas emissions from your plant.

All are fully flexible and can be customised to incorporate site name, appliance reference, make, model, size, and our operator number.

Data can be exported into some of the more commonly used spreadsheets like Excel and Lotus, as well as a basic tabular formats.

You are able to modify many of the functions of the Grapher in the Set-up option, ranging from your Printer setup to assigning preferred gas and temperature unit types.

This will help you obtain the most from Grapher while it extracts the optimum from your Kane-May Analyser.

 

Shows data in 25mm high characters, ideal for training or for monitoring in "real time".

bullet The Reporter Software will display and create reports for each boiler test providing an essential hard copy of your client.
bullet Its large simulated LED display option shows clearly your combustion tests for analysis.
bullet This fully flexible package lets you easily change displayed parameters and units using pre-set groups.
bullet Simple to use Windows technology using push button and keyboard controls.
bullet Take data from your Quintox in real time, from the handset or from a PC file.
bullet See real-time or stored data in graphs or tables in Windows format.
bullet Print boiler performance, safety and emissions reports.
bullet View data in table format.
bullet Export to a Spreadsheet.
bullet Display data in large LED format - Ideal for training.
bullet Easy to use buttons and screens in Windows.
bullet Runs on 386 PC compatible or higher.
bullet Simple to use Windows technology using push button and keyboard controls.

Kane-May’s new Fireworks software is the easiest way to see data from your Quintox on a PC. You can transfer data from the handset, see data in "real time" or see previously stored data.

Fireworks uses Windows software giving full flexibility to view, manage and report on boiler performance and emissions data. Producing graphs or reports takes the press of a button.

Graph data in real-time,  from logged data in
the handset or from a previously stored file.

Fireworks lets you make professional reports for your customers or your records. In addition standard reports can be customised, for example:

bullet Boiler emissions
bullet Compute automatically outputs per year of CO, CO2, Nox and SO2.
bullet Boiler safety
bullet Show the CO/CO2 ratio or Poison Index and efficiency of domestic boilers
bullet Boiler performance
bullet Create "Before & After" reports to show boiler performance & efficiency after servicing.
bullet Boiler spot check

Ideal for a simple record of all boiler parameters

Connect the Quintox RS232 port to your PC’s serial port to view data in "real time", updated every second - Perfect if you use a laptop PC to view boiler performance data.

Either run a report showing pollution emissions converted to daily, monthly and yearly figures or run before and after tuning reports to show efficiency improvements.

Once data is loaded it can be viewed on screen or used to generate reports.  Once the data is analysed reports can be generated to give your client a spot check or boiler tuning, i.e. before or after results.

Copies of the report can be generated on site or more commonly back in the office to be sent with other information such as work reports and invoices.

Data and reports can be stored as reporter files for future use or saved to other formats for use in word processors or spreadsheets, or transfer data stored in the Quintox handset via the PC serial port.

Home / Up

 
Email for More Information: moreinfo@sotaew.co.uk   
Copyright © 2005 State Of The Art, Last modified: 12/28/06